1. Nichols JJ, Fisher D. Contact lenses 2020. Contact Lens Spectr. 2021;36:24-29.
2. Kakroo V. Contact lenses market size, share, and trends 2024 to 2033. Precedence Research. 2024. URL: https://www.precedenceresearch.com/contact-lenses-market (accessed 23.12.2024).
3. Джонс Л, Уолш К. Эволюция однодневных силикон-гидрогелевых линз. Два десятилетия инноваций в области материалов и дизайнов. Вестник оптометрии. 2018;4:22-28.
4. Stern J, Wong R, Naduvilath TJ, et al. Comparison of the performance of 6- or 30-night extended wear schedules with silicone hydrogel lenses over 3 years. Optometry and Vision Science. 2004;81(6):398-406. DOI: 10.1097/01.opx.0000135092.69383.fd
5. Nilsson SE. Seven-day extended wear and 30-day continuous wear of high oxygen transmissibility soft silicone hydrogel contact lenses: A randomized 1-year study of 504 patients. CLAO Journal. 2001;27(3):125-136.
6. Перфильева ЕА. Эволюция материалов и дизайна мягких контактных линз. The EYE ГЛАЗ. 2018;20(2):10-14. EDN: DIKRLX
7. Киреев ВВ. Высокомолекулярные соединения: учебник для академического бакалавриата. М.: Юрайт; 2015:602.
8. Musgrave CSA, Fang F. Contact lens materials: A materials science perspective. Materials (Basel). 2019;12(2):261. DOI: 10.3390/ma12020261
9. Wuchte L, DiPasquale S, Masterson A, et al. Characterization and analysis of extended-wear silicone hydrogel contact lenses utilizing novel silicone macromers. J Biomed Mater Res A. 2022;110(8):1512-1523. DOI: 10.1002/jbm.a.37389
10. dos Santos JF, Alvarez-Lorenzo C, Silva M, et al. Soft contact lenses functionalized with pendant cyclodextrins for controlled drug delivery. Biomaterials. 2009;30(7):1348-1355. DOI: 10.1016/j.biomaterials.2008.11.016 EDN: KPEKXR
11. Zhao Z, Xie H, An S, Jiang Y. The relationship between oxygen permeability and phase separation morphology of the multicomponent silicone hydrogels. J Phys Chem B. 2014;118(50):14640-14647. DOI: 10.1021/jp507682k EDN: URDOPP
12. Moad G. A critical assessment of the kinetics and mechanism of initiation of radical polymerization with commercially available dialkyldiazene initiators. Progress in Polymer Science. 2019;88:130-188. DOI: 10.1016/j.progpolymsci.2018.08.003 EDN: FOKUZB
13. Alió JL, Belda JI, Artola A, et al. Contact lens fitting to correct irregular astigmatism after corneal refractive surgery. Cataract Refract Surg. 2002;28(10):1750-1757. DOI: 10.1016/s0886-3350(02)01489-x
14. Shishavan AA, Nordin L, Tjossem P, et al. PMMA-based ophthalmic contact lens for vision correction of strabismus. Proceedings of the SPIE. 2016;9918. DOI: 10.1117/12.2237994
15. Thean, JHJ, Mcnab AA. Blepharoptosis in RGP and PMMA hard contact lens wearers. Clin Exp Optom. 2004;87(1):11-14. DOI: 10.1111/j.1444-0938.2004.tb03139.x
16. Michálek J., Podešva J., Dušková-Smrčková M. True story of poly(2-hydroxyethyl methacrylate)-based contact lenses: How did it really happen. Substantia. 2022;6(2):79-91. DOI: 10.36253/Substantia-1591 EDN: TQFLUT
17. Kopecek J. Hydrogels: From soft contact lenses and implants to self-assembled nanomaterials. Journal of polymer science / Part A. Polymer chemistry. 2009;47(22):5929-5946. DOI: 10.1002/pola.23607
18. Wichterle O, Lim D. Hydrophilic gels for biological use. Nature. 1960;185:117-118. DOI: 10.1038/185117a0
19. Wichterle O. Method of centrifugally casting thin edged corneal contact lenses. Patent US3660545A - 1972-05-02.
20. Nicolson PC, Vogt J. Soft contact lens polymers: an evolution. Biomaterials. 2001;22(24):3273-3283. DOI: 10.1016/s0142-9612(01)00165-x EDN: ARXSPB
21. Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci. 1984;25(10):1161-1167.
22. Harvitt DM, Bonanno JA. Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. Optom Vis Sci. 1999;76(10):712-719. DOI: 10.1097/00006324-199910000-00023
23. Tighe BJ. Extended wear contact lenses. Biomaterials and Regenerative Medicine in Ophthalmology. 2010;304-336.
24. Воронков МГ, Милешкевич ВП, Южелевский ЮА. Силоксановая связь. Новосибирск: Наука; 1976:413.
25. Kossovsky N, Freiman CJ. Physicochemical and immunological basis of silicone pathophysiology. J Biomater Sci Polym Ed. 1995;7(2):101-113. DOI: 10.1163/156856295x00625
26. Habal MB. The biologic basis for the clinical application of the silicones. A correlate to their biocompatibility. Arch Surg. 1984;119(7):843-848. 10.1001/ archsurg.1984.01390190081019. DOI: 10.1001/archsurg.1984.01390190081019
27. Key JE. Development of contact lenses and their worldwide use. Eye & Contact Lens. 2007;33(6):343-345. DOI: 10.1097/ICL.0b013e318157c230
28. Gaylord NG. Oxygen-permeable contact lens composition methods and article of manufacture. Patent US3808178 - 30- 04-1974.
29. Nicholson PC, Baron RC, Chabrecek P, et al. Extended wear ophthalmic lens. Patent WO 96/31792 - 22-03-1996.
30. Ishihara K, Shi X, Fukazawa K, et al. Biomimetic-engineered silicone hydrogel contact lens materials. ACS Appl Bio Mater. 2023;6(9):3600-3616. DOI: 10.1021/acsabm.3c00296 EDN: PEZCDA
31. Harvey TB. Hydrophilic siloxane monomers and dimmers for contact lens materials and contact lenses fabricated therefrom. Patent US4711943 - 08-12-1987.
32. Iwata J, Hoki T, Ikawa S, Back A. Silicone hydrogel contact lens. Patent US8614261B2 - 20-09-2006.
33. Broad RA. Contact lens. Patent WO2008061992 - 29-05- 2008.
34. Ishihara K, Ueda T, Nakabayashi N. Preparation of phospholipid polymers and their properties as polymer hydrogel membranes. Polym J. 1990;22(5):355-360. DOI: 10.1295/polymj.22.355
35. Willis SL, Court JL, Redman RP, et al. A novel phosphorylcholinecoated contact lens for extended wear use. Biomaterials. 2001;22(24):3261-3272. DOI: 10.1016/S0142-9612(01)00164-8 EDN: ARXSOR
36. Ишихара К, Папас Э, Пруитт Д и др. Инновации в контактной коррекции: создание биомиметической поверхности. The EYE ГЛАЗ. 2023;25(3):235-243. DOI: 10.33791/2222-4408-2023-3-235-243 EDN: DRORPU